Results 1 - 20 de 2.068
Filter
1.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1551332

ABSTRACT

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Subject(s)
Dental Implants , Dental Prosthesis , Finite Element Analysis , Biomechanical Phenomena
2.
São José dos Campos; s.n; 2024. 81 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1552084

ABSTRACT

O objetivo deste estudo foi avaliar o comportamento biomecânico através da resistência à fadiga e análise por elementos finitos de coroas bioinspiradas bilaminadas com infraestruturas modificadas na superfície vestibular (Estudo A) e utilizando diferentes materiais cerâmicos com módulos elásticos distintos (Estudo B). Para isso, foram confeccionados 90 preparos para coroa total em resina epóxi G10, sobre os quais foram preparadas coroas bioinspiradas de acordo com os seguintes grupos: Estudo A - IC (infraestrutura convencional), IME (infraestrutura modificada estratificada) e IMC (infraestrutura modificada cimentada), todas confeccionadas em dissilicato de lítio (infraestrutura) + porcelana (recobrimento); Estudo B ­ DL+LEU (dissilicato de lítio + leucita), LEU+DL (leucita + dissilicato de lítio), CH+DL (cerâmica híbrida + dissilicato de lítio) e CH+LEU (cerâmica híbrida + leucita). Para o Estudo A, todas as infraestruturas foram usinadas; os recobrimentos dos grupos IC e IME foram confeccionados através da estratificação, e os recobrimentos do grupo IMC foram usinados. Já para o Estudo B, todas as peças foram usinadas, de acordo com o material cerâmico de cada grupo. Em seguida, foi realizada a cimentação adesiva dos recobrimentos sobre as infraestruturas (a depender do grupo) e das coroas sobre os preparos utilizando cimento resinoso fotopolimerizável (Variolink Esthetic LC). Após a cimentação, os espécimes foram submetidos ao teste de fadiga cíclica (10.000 ciclos, 20Hz), e como desfecho foram considerados dois eventos, em que o primeiro foi a ocorrência de trinca e/ou lascamento (evento 1) e o segundo foi a falha catastrófica do conjunto (evento 2). Os valores de carga e número de ciclos para falha em que foram observados os eventos 1 e 2 foram utilizados para realizar a análise de sobrevivência de acordo com Kaplan-Meier e Log-Rank (Mantel-Cox; 95%). As marcas de fratura e o modo de falha das coroas foram avaliados e classificados por estereomicroscópio óptico e microscópio eletrônico de varredura. Por fim, foi realizada análise por elementos finitos (FEA) para ambos os estudos, a fim de avaliar a distribuição de tensões sobre as coroas e interface adesiva. Para o Estudo A, os resultados do teste de fadiga mostraram que, considerando o evento 1 (trinca/lascamento), os grupos IC e IMC apresentaram médias de carga fadiga estatisticamente significantes entre si (733,33 N e 913,33 N, respectivamente), enquanto o grupo IME apresentou média superior (1.020 N). O mesmo foi observado para o número de ciclos em fadiga para todos os grupos. Ao considerar o evento 2 (falha catastrófica), os três grupos apresentaram médias estatisticamente semelhantes entre si (~1.028 N). Os resultados de FEA mostraram que o grupo IC concentrou maior tensão de tração do que os grupos IME e IMC. Para o Estudo B, no teste de fadiga, o grupo DL+LEU apresentou a maior média de resistência à fadiga (evento 1: 913,33 N e evento 2: 1033,33 N), enquanto todas as outras combinações de materiais cerâmicos analisadas foram estatisticamente semelhantes entre si, considerando carga e número de ciclos. Com relação ao FEA, os grupos com cerâmica híbrida (CH+DL e CH+LEU) apresentaram menores picos de concentração de tensão na infraestrutura do que os grupos com cerâmicas vítreas (DL+LEU e LEU+DL), porém, em contrapartida, concentraram maior tensão na interface adesiva. Com isso, conclui-se que a utilização da infraestrutura modificada é uma alternativa viável e promissora para tratamentos reabilitadores, apresentando sobrevivência em fadiga e distribuição de tensões satisfatórias. Além disso, a combinação entre uma infraestrutura de dissilicato de lítio e recobrimento de cerâmica a base de leucita corresponde a melhor abordagem considerando a infraestrutura modificada.(AU)


The objective of this study was to evaluate the biomechanical behavior through fatigue resistance and finite element analysis of bilaminar bioinspired crowns with modified infrastructures on the buccal surface (Study A) and using different ceramic materials with different elastic moduli (Study B). For this, 90 preparations were made for a full crown in G10 epoxy resin, on which bioinspired crowns were prepared according to the following groups: Study A - CI (conventional infrastructure), SMI (stratified modified infrastructure) and CMI (cemented modified infrastructure ), all made of lithium disilicate (infrastructure) + porcelain (veneer); Study B ­ LD+LEU (lithium disilicate + leucite), LEU+LD (leucite + lithium disilicate), HC+LD (hybrid ceramic + lithium disilicate) and HC+LEU (hybrid ceramic + leucite). For Study A, all infrastructures were machined; the coverings of the CI and SMI groups were made through stratification technique, and the veneers of the SMI group were machined. For Study B, all pieces were machined, according to the ceramic material of each group. Then, the veneers were cemented into their infrastructures (depending on the group) and crowns were cemented into preparations using light-cured resin cement (Variolink Esthetic LC). After cementing, the specimens were subjected to the cyclic fatigue test (10,000 cycles, 20Hz), and as an outcome two events were considered: the occurrence of cracking and/or chipping (event 1) and catastrophic failure (event 2). The load (N) and number of cycles to failure in which events 1 and 2 were observed were used to perform the survival analysis according to Kaplan-Meier and Log-Rank (Mantel- Cox; 95%). The fracture marks and failure mode of the crowns were evaluated and classified by optical stereomicroscope and scanning electron microscope. Finally, finite element analysis (FEA) was performed for both studies in order to evaluate the stress distribution over the crowns and adhesive interface. For Study A, the results of the fatigue test showed that, considering event 1 (cracking/chipping), the CI and CMI groups presented average to failure that were statistically significant compared to each other (733.33 N and 913.33 N, respectively), while the SMI group showed higher averages (1,020 N). Same pattern was observed for the number of cycles under fatigue for both groups. When considering event 2 (catastrophic failure), the three groups presented statistically similar means (~1,028 N). The FEA results showed that the CI group concentrated greater tensile stress than the CMI and SMI groups. For Study B, in the fatigue test, the LC+LEU group presented the highest average fatigue resistance (event 1: 913.33 N and event 2: 1033.33 N), while all other combinations of ceramic materials analyzed were statistically similar to each other, considering load and number of cycles. Regarding FEA, the groups with hybrid ceramics (HC+LC and HC+LEU) showed lower stress concentration peaks in the infrastructure than the groups with glass ceramics (LC+LEU and LEU+LC), however, on the other hand, concentrated greater tension at the adhesive interface. With this, it is concluded that the use of modified infrastructure is a viable and promising alternative for oral rehabilitation treatments, presenting satisfactory fatigue survival and adequate stress distribution. Furthermore, the combination of a lithium disilicate infrastructure and a leucite-based ceramic coating corresponds to the best approach considering the modified infrastructure.(AU)


Subject(s)
Ceramics , Finite Element Analysis , Biomimetics , Denture, Partial, Fixed , Fatigue
3.
Dental press j. orthod. (Impr.) ; 29(1): e2423195, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1534312

ABSTRACT

ABSTRACT Introduction: Surgically assisted rapid palatal expansion (SARPE) has been the treatment of choice in subjects presenting skeletally mature sutures. Objective: The purpose of this study was to analyze stress distribution and displacement of the craniofacial and dentoalveolar structures resulting from three types of palatal expanders with surgical assistance using a non-linear finite element analysis. Material and Methods: Three different palatal expanders were designed: Model-I (tooth-bone-borne type containing four miniscrews), Model-II (tooth-bone-borne type containing two miniscrews), and Model-III (bone-borne type containing four miniscrews). A Le Fort I osteotomy was performed, and a total of 5.0 mm palatal expansion was simulated. Nonlinear analysis (three theory) method (geometric nonlinear theory, nonlinear contact theory, and nonlinear material methods) was used to evaluate stress and displacement of several craniofacial and dentoalveolar structures. Results: Regardless of the maxillary expander device type, surgically assisted rapid palatal expansion produces greater anterior maxillary expansion than posterior (ANS ranged from 2.675 mm to 3.444 mm, and PNS ranged from 0.522 mm to 1.721 mm); Model-I showed more parallel midpalatal suture opening pattern - PNS/ANS equal to 54%. In regards to ANS, Model-II (1.159 mm) and Model-III (1.000 mm) presented larger downward displacement than Model-I (0.343 mm). PNS displaced anteriorly more than ANS for all devices; Model-III presented the largest amount of forward displacement for PNS (1.147 mm) and ANS (1.064 mm). All three type of expanders showed similar dental displacement, and minimal craniofacial sutures separation. As expected, different maxillary expander designs produce different primary areas and levels of stresses (the bone-borne expander presented minimal stress at the teeth and the tooth-bone-borne expander with two miniscrews presented the highest). Conclusions: Based on this finite element method/finite element analysis, the results showed that different maxillary expander designs produce different primary areas and levels of stresses, minimal displacement of the craniofacial sutures, and different skeletal V-shape expansion.


RESUMO Introdução: A expansão rápida da maxila assistida cirurgicamente (ERMAC) tem sido o tratamento de escolha em indivíduos que apresentam suturas esqueleticamente maduras. Objetivo: O objetivo deste estudo foi avaliar, utilizando uma análise não linear com elementos finitos, a distribuição de tensões e os deslocamentos das estruturas craniofaciais e dentoalveolares gerados por três tipos de expansores palatinos usados na ERMAC. Material e Métodos: Três tipos de expansores palatinos foram projetados: Modelo I (dento-osseossuportado com quatro mini-implantes), Modelo II (dento-osseossuportado com dois mini-implantes) e Modelo III (osseossuportado com quatro mini-implantes). Uma osteotomia Le Fort I foi realizada e foi simulada uma expansão palatina total de 5,0 mm. Um método de análise não linear (três teorias - teoria da não-linearidade geométrica, teoria do contato não linear e métodos para materiais não lineares) foi utilizado para avaliar a tensão e o deslocamento de diversas estruturas craniofaciais e dentoalveolares. Resultados: Independentemente do tipo de aparelho expansor palatino, a ERMAC produziu maior expansão anterior da maxila do que posterior (ENA variou de 2,675 mm a 3,444 mm e ENP variou de 0,522 mm a 1,721 mm); o Modelo I apresentou padrão de abertura mais paralela da sutura palatina mediana, com ENP/ENA igual a 54%. Com relação à ENA, o Modelo II (1,159 mm) e o Modelo III (1,000 mm) apresentaram maior deslocamento para baixo do que o Modelo I (0,343 mm). A ENP deslocou-se mais para anterior do que a ENA com todos os aparelhos; o Modelo III apresentou o maior deslocamento para anterior da ENP (1,147 mm) e da ENA (1,064 mm). Os três tipos de expansores apresentaram deslocamento dentário semelhante e separação mínima das suturas craniofaciais. Como esperado, diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensões (o expansor osseossuportado apresentou tensão mínima nos dentes, e o expansor dento-osseossuportado com dois mini-implantes apresentou o maior). Conclusões: Com base nesse estudo de elementos finitos, os resultados mostraram que diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensão, com deslocamento mínimo das suturas craniofaciais e diferentes expansões esqueléticas em forma de V.

4.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 188-195, 2024.
Article in Chinese | WPRIM | ID: wpr-1006520

ABSTRACT

Objective@#To explore the effect of different miniscrew placement heights on the distribution of biological forces produced by clear aligner combined with intramaxillary traction for mandibular molar distalization, to identify the miniscrew location that is conducive to the protection of lower anterior tooth anchorage and to provide a reference that can be used when designing clinical treatments.@*Methods@#Mimics, GeomagicStudio 2017, SolidWorks 2016, and Ansys workbench were used to establish finite element analysis models and perform mechanical analysis under the following six working conditions: working condition 1 was the control group without miniscrews; working conditions 2 to 5 had miniscrew in the buccal bone cortex between the first and second molars of the lower jaw 10 mm, 7 mm, 4 mm, and 1 mm from the top of the alveolar crest, respectively; working condition 6 had the miniscrew in the center of the buccal tongue at the anterior edge of the ascending branch of the lower jaw 5 mm above the occlusal plane.@*Results@#On the sagittal axis, miniscrew anchorage caused distal displacement of all teeth. Compared to the control group, in the miniscrew group, the displacement of the anterior molars exceeded that of the second molars. On the vertical axis, the result in the control group was similar to backward bending; the results in the miniscrew groups resembled the effect of a lever, lowering the lateral incisors and canines and raising the central incisors and first premolars. On the coronal axis, the second premolars and the first molars showed lingual displacement in the control group, and only the premolars and first molars showed lingual displacementin the miniscrew groups. The canines were the teeth that were most strongly affected by the change in miniscrew placement height.@*Conclusion@#The higher the miniscrew position is, the stronger the protective effect on the anterior anchorage. According to the miniscrew placement height, the mandibular arch should be properly narrowed, the central incisors and first premolars should be lowered, and the lateral incisors and canines should be raised when designing clinical treatments.

5.
International Eye Science ; (12): 62-66, 2024.
Article in Chinese | WPRIM | ID: wpr-1003507

ABSTRACT

The finite element method(FEM)is a widely employed mathematical technique in mechanical research that divides an object into discrete and interacting finite elements. Medically, finite element analysis(FEA)enables the simulation of biomechanical experiments that are challenging to conduct. Orbital surgery poses significant challenges to ophthalmologists due to its inherent difficulty and steep learning curve. FEM enables the simulation and analysis of the mechanical properties of orbital tissue, offering a novel approach for diagnosing and treating orbital-related diseases. With technological advancements, FEM has significantly matured in the diagnosis and treatment of orbital diseases, becoming a popular area of research in orbital biomechanics. This paper reviewed the latest advancements in orbital FEM, encompassing the development of orbital FEA models, simulation of orbital structure, and its application in orbital-related diseases. Additionally, the limitations of FEM and future research directions are also discussed. As a digital tool for auxiliary diagnosis and treatment, orbital FEA will progressively unlock its potential for diagnosing and treating orbital diseases alongside technological advancements.

6.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1537357

ABSTRACT

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Subject(s)
Osteotomy, Le Fort , Finite Element Analysis , Orthognathic Surgery , Fracture Fixation, Internal
7.
Int. j. morphol ; 41(5): 1288-1296, oct. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1521049

ABSTRACT

El propósito de este estudio fue analizar el comportamiento mecánico de la estructura dental sana de un primer premolar inferior humano sometido a fuerzas funcionales y disfuncionales en diferentes direcciones. Se buscó comprender, bajo las variables contempladas, las zonas de concentración de esfuerzos que conllevan al daño estructural de sus constituyentes y tejidos adyacentes. Se realizó el modelo 3D de la reconstrucción de un archivo TAC de un primer premolar inferior, que incluyó esmalte, dentina, ligamento periodontal y hueso alveolar considerando tres variables: dirección, magnitud y área de la fuerza aplicada. La dirección fue dirigida en tres vectores (vertical, tangencial y horizontal) bajo cuatro magnitudes, una funcional de 35 N y tres disfuncionales de 170, 310 y 445 N, aplicadas sobre un área de la cara oclusal y/o vestibular del premolar que involucró tres contactos estabilizadores (A, B y C) y dos paradores de cierre. Los resultados obtenidos explican el fenómeno de combinar tres vectores, cuatro magnitudes y un área de aplicación de la fuerza, donde los valores de esfuerzo efectivo equivalente Von Mises muestran valores máximos a partir de los 60 MPa. Los valores de tensión máximos se localizan, bajo la carga horizontal a 170 N y en el proceso masticatorio en la zona cervical, cuando la fuerza pasa del 60 %. Sobre la base de los hallazgos de este estudio, se puede concluir que la reacción de los tejidos a fuerzas funcionales y disfuncionales varía de acuerdo con la magnitud, dirección y área de aplicación de la fuerza. Los valores de tensión resultan ser más altos bajo la aplicación de fuerzas disfuncionales tanto en magnitud como en dirección, produciendo esfuerzos tensiles significativos para la estructura dental y periodontal cervical, mientras que, bajo las cargas funcionales aplicadas en cualquier dirección, no se generan esfuerzos lesivos. Esto supone el reconocimiento del poder de detrimento estructural del diente y periodonto frente al bruxismo céntrico y excéntrico.


SUMMARY: The purpose of this study was to analyze the mechanical behavior of the healthy dental structure of a human mandibular first premolar subjected to functional and dysfunctional forces in different directions. It was sought to understand, under the contemplated variables, the areas of stress concentration that lead to structural damage of its constituents and adjacent tissues. The 3D model of the reconstruction of a CT file of a lower first premolar was made, which included enamel, dentin, periodontal ligament and alveolar bone considering three variables: direction, magnitude and area of the applied force. The direction was directed in three vectors (vertical, tangential and horizontal) under four magnitudes, one functional of 35 N and three dysfunctional of 170, 310 and 445 N, applied to an area of the occlusal and/or buccal face of the premolar that involved three stabilizing contacts (A, B and C) and two closing stops. The results obtained explain the phenomenon of combining three vectors, four magnitudes and an area of force application, where the values of effective equivalent Von Mises stress show maximum values from 60 MPa. The maximum tension values are located under the horizontal load at 170 N and in the masticatory process in the cervical area, when the force exceeds 60%. Based on the findings of this study, it can be concluded that the reaction of tissues to functional and dysfunctional forces varies according to the magnitude, direction, and area of application of the force. The stress values turn out to be higher under the application of dysfunctional forces both in magnitude and in direction, producing significant tensile stresses for the dental and cervical periodontal structure, while under functional loads applied in any direction, no damaging stresses are generated. This supposes the recognition of the power of structural detriment of the tooth and periodontium against centric and eccentric bruxism.


Subject(s)
Humans , Bicuspid/physiology , Biomechanical Phenomena , Finite Element Analysis , Tooth/physiology , Bite Force , Bruxism/physiopathology , Elastic Modulus , Tooth Wear , Mastication/physiology
8.
Kinesiologia ; 42(2): 127-131, 20230615.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552472

ABSTRACT

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

9.
Int. j. odontostomatol. (Print) ; 17(2): 174-185, jun. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1440356

ABSTRACT

This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical and cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into the jaw model in each model. The implants consisted of Titanium (Ti-S group) and Zirconia Monotype/one-piece (Zr-S group). Fixed full-arch implant-supported prostheses were cemented onto the implant. The models were exported to the analysis software and divided into meshes composed of nodes and tetrahedral elements. All materials were considered isotropic, elastic, and homogeneous. Therefore, all contacts were considered bonded, the mandible model was fixed in all directions, applying a static structural axial load of 300 N on the bottom of the fossa of the left mola r teeth. Microstrain and von-Mises stress (MPa) were adopted as failure criteria. Comparable stress and strain values were shown in the peri-implant bone for both groups. However, the Ti-S group presented a lower stress value (1,155.8 MPa) than the Zr-S group (1,334.2 MPa). Regarding bone tissues, the Ti-S group presented 612 µε and the Zr-S group presented 254 µε. The highest strain peak was observed in bone tissues around the implant closer to the load for both groups. Evaluating monotype zirconia and titanium implants, it is suggested that the greater the rigidity of the implant, the greater the concentration of internal stre sses and the less dissipation to the surrounding tissues. Therefore, monotype ceramic implants composed of yttrium-stabilized tetragonal polycrystalline zirconia may be a viable alternative to titanium implants for full-arch prostheses.


El objetivo de este estudio in silico fue evaluar el comportamiento biomecánico de una prótesis implanto soportada de arcada completa sobre implantes monotipo de titanio y zirconia. Se modeló una mandíbula en 3D que contenía tejido óseo cortical y esponjoso de 1,0 mm de espesor. En cada modelo, se insertaron cuatro implantes dentales (3,3 x 10 mm) en el modelo de mandíbula. Los implantes consistieron en Monotipo de Titanio y Zirconia. Sobre el implante se cementaron prótesis implanto soportadas de arcada completa fija. Los modelos se exportaron al software de análisis y se dividieron en mallas compuestas por nodos y elementos tetraédricos. Todos los materiales se consideraron isotrópicos, elásticos y homogéneos. Por lo tanto, todos los contactos se consideraron cementados, el modelo mandibular se fijó en todas las direcciones, aplicando una carga vertical estructural estática de 300 N en el fondo de la fosa de los dientes molares izquierdos. Se seleccionaron la microesfuerzo y la tensión de Von-Mises (MPa) como criterios de falla. Se mostraron valores de tensión y deformación comparables en el hueso periimplantario para ambos grupos. Sin embargo, el grupo Ti-S presentó un valor de estrés menor (1.155,8 MPa) que el grupo Zr-S (1.334,2 MPa). En cuanto a los tejidos óseos, el grupo Ti-S presentó 612 µε y el grupo Zr-S presentó 254 µε. La mayor concentración de deformación en el tejido óseo se observó en los tejidos alrededor del implante más cerca de la carga para ambos grupos. Al evaluar los implantes monotípicos de zirconia y titanio, se sugiere que cuanto mayor sea la rigidez del implante, mayor será la concentración de tensiones internas y menor la disipación a los tejidos circundantes. Por lo tanto, los implantes cerámicos monotipo compuestos de zirconia policristalina tetragonal estabilizada con itrio pueden ser una alternativa viable a los implantes de titanio para prótesis de arcada completa.


Subject(s)
Dental Implants , Dental Materials , Stress, Mechanical , Biomechanical Phenomena , Finite Element Analysis , Mandible/diagnostic imaging
10.
Arq. bras. oftalmol ; 86(2): 178-187, Mar.-Apr. 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429834

ABSTRACT

ABSTRACT After the discovery of anti-vascular endothelial growth factor agents as treatment of wet age-related macular degeneration, the number of studies with the objective to understand the molecular mechanisms involved in the age-re lated macular degeneration genesis has increased. The importance of the nuclear factor e2-related factor 2 lies in its activation-derived proteins being involved in the maintenance of the redox balance and consequent prevention of degenerative macular disease. This article aims to present the characteristics of nuclear factor e2-related factor 2 and describe the main nuclear factor e2-related factor 2-activated antioxidant enzymes that contribute to the preservation of vision.


RESUMO Após a descoberta do anti fator de crescimento en dotelial vascular no tratamento da degeneração macular relacionada à idade úmida, muitas pesquisas têm sido realizadas com o intuito de elucidar os mecanismos moleculares envolvidos na gênese da degeneração macular relacionada à idade. O fator nuclear eritroide 2 relacionado ao fator 2 destaca-se pelo fato de diversas proteínas, oriundas de sua ativação, estarem envolvidas na manutenção do equilíbrio do estado redox e consequente prevenção da doença macular degenerativa. Este artigo mostra as características do fator nuclear eritroide 2 relacionado ao fator 2 e descreve as principais enzimas antioxidantes originadas da ativação que contribuem para a preservação da visão.

11.
Chinese Journal of Orthopaedics ; (12): 308-315, 2023.
Article in Chinese | WPRIM | ID: wpr-993443

ABSTRACT

Objective:To compare the biomechanical differences of dynamic condylar screw (DCS), locking compression plate (LCP) combined with DCS and medial anatomic buttress plate (MABP) combined with DCS in the revision of medial defective intertrochanteric fractures by finite element analysis.Methods:The femoral CT imaging data provided by a healthy adult volunteer were used to reconstruct the solid three-dimensional model of femur by Mimics 21.0 and Geomagics Studio 12. Evans-Jensen II B intertrochanteric fracture was established by Ansys Workbench18.0. The three-dimensional models of proximal femoral nail antirotation (PFNA), DCS, LCP and MABP were reconstructed in Solidworks 2015. The PFNA was assembled with the fracture model, and then the PFNA was removed to establish the postoperative failure model of femoral intertrochanteric fracture and then simulated the fixation in the hip-preserving revision surgery of femoral intertrochanteric fractures: non-medial support reconstruction group (DCS); indirect medial support reconstruction group (DCS+LCP) and partial direct medial support reconstruction group (DCS+MABP). Finally, the forces on the hip joint of 70 kg normal people during standing (700 N), slow walking (1,400 N), brisk walking (1,750 N) and going up and down stairs (2,100 N) were simulated in Abaqus 6.14, the relative displacement and stress peak value of fracture end and stress distribution and stress peak value of internal fixation in different models were recorded.Results:At 700 N axial load, the relative displacement of fracture end fixed by DCS, DCS+LCP and DCS+MABP was 0.28, 0.13 and 0.09 mm; the peak stress of the fracture end was 49.01, 15.29 and 1.35 MPa; the peak stress of internal fixation was 230, 220 and 174 MPa, respectively. At 1,400 N axial load, the relative displacement of the fracture end of the three internal fixation methods was 0.56, 0.24 and 0.16 mm; the peak stress of fracture end was 108.49, 28.96 and 3.12 MPa; the peak stress of internal fixation was 469, 352 and 324 MPa, respectively. At 1,750 N axial load, the relative displacement of the fracture end of the three group was 0.70, 0.30 and 0.20 mm; the peak stress of the fracture end was 139.59, 37.57 and 4.17 MPa; the peak stress of internal fixation was 594, 421 and 393 MPa, respectively. At 2,100 N axial load, the relative displacement of the fracture end of the three internal fixation methods was 0.85, 0.35 and 0.23 mm; the peak stress of the fracture end was 170.05, 46.36 and 5.24 MPa; the peak stress of internal fixation was 724, 504 and 460 MPa, respectively.Conclusion:The partial direct reconstruction of medial support under the neck by DCS+MABP may have better biomechanical properties in the revision of medial defective intertrochanteric fractures.

12.
Journal of Chinese Physician ; (12): 700-703,708, 2023.
Article in Chinese | WPRIM | ID: wpr-992364

ABSTRACT

Objective:To establish a three-dimensional model of locking plate fixation for 42A2 type oblique tibial fractures with different fracture line directions and different angles between the fracture line and the long axis of the tibia. Finite element analysis was used to calculate and analyze the biomechanics of locking plate, screw, and tibia, providing theoretical basis for clinical application.Methods:A healthy adult volunteer, 25 years old, male, with a height of 173 cm and a weight of 69.5 kg, was selected to perform computed tomography (CT) scans on the left tibia. Relevant data were obtained to establish a locking steel plate fixation model for 42A2 type tibia with different oblique fracture line directions and different angles between the fracture line and the long axis of the tibia. Eight hole pure titanium plates were used for fixation, respectively. We compared the Mises stress changes of locking plates, screws, and tibia in different angle fracture models.Results:In the case of a 42A2 type fracture in the left oblique direction with a fracture line from outside to inside, the maximum Mises stress in the tibia was 114 MPa, the maximum Mises stress in the screw was 279.8 MPa, and the maximum Mises stress in the locking steel plate was 302.4 MPa; In the case of a 42A2 type fracture in the right oblique fracture with a fracture line from the bottom to the top, the maximum Mises stress of the tibia was 93.41MPa, the maximum Mises stress of the screw was 353.4 MPa, and the maximum Mises stress of the locking steel plate was 411.8 MPa.Conclusions:Regardless of the oblique fractures in both left and right directions, the maximum stress values are: locking plate>screw>tibia; When the position of the locking steel plate is fixed, the maximum stress values of the locking steel plate and screw are both right oblique fracture>left oblique fracture; And the maximum stress values all increase with the increase of angle.

13.
Chinese Journal of Endemiology ; (12): 507-510, 2023.
Article in Chinese | WPRIM | ID: wpr-991663

ABSTRACT

Objective:To establish a method for automatic determination of iodine level in salt by arsenic-cerium catalytic spectrophotometry using an iodine element detector (hereinafter referred to as this method), and to provide reference for in-depth study of salt iodine detection technology.Methods:This method was used to determine the iodine level in salt, and the linear range, detection limit, precision, and accuracy (determination of salt iodine standard substance GBW10006y and GBW10007y, and addition recovery experiment) of this method were determined. The iodine level of 35 salt samples was determined by this method and redox titration method recommended by the national standard, and the results were compared.Results:This method had a good linear relationship within the range of 50 - 600 μg/L standard curve, the absolute value of the correlation coefficients was > 0.999 0, and the detection limit was 5.0 mg/kg. The relative standard deviation of iodine concentration in salt samples with low, medium and high iodine concentrations were all < 6.0%. The determination results of salt iodine standard substance GBW10006y and GBW10007y were within the given value ranges; three iodine concentrations (6.0, 10.0 and 30.0 mg/kg) were added to the salt samples, with an average recovery rate of 96.7% to 105.0%, and a total average recovery rate of 100.9%. The method comparison experiment showed that there was no statistically significant difference between the salt iodine determination results of this method and the redox titration method ( t = - 1.54, P = 0.132). Conclusion:This method has the advantages of high accuracy, good precision and wide linear range in determining salt iodine, and is suitable for the detection of large quantities of samples in salt iodine monitoring.

14.
STOMATOLOGY ; (12): 222-227, 2023.
Article in Chinese | WPRIM | ID: wpr-979358

ABSTRACT

Objective@#To analyze and investigate the effects of implant location and axial direction on the stress distribution of implants, abutments, central screws, and crowns during immediate loading of maxillary mesial incisors with different alveolar fossa morphology based on three-dimensional finite element method.@*Methods@#Referring to the oral CBCT images of a healthy adult, a three-dimensional finite element model was established for immediate implant loading of maxillary central incisors with three alveolar fossa morphs: labial, intermediate, and palatal; different implant sites(apical site, palatal/labial site) and axes(tooth long axis, alveolar bone long axis) were simulated; the established model was loaded with a force of 100 N. ANSYS software was applied to analyze the stress values of the implants, abutments, central screwss, and crownss. @*Results@#The 3D finite element models of 12 maxillary central incisors with different alveolar sockets were successfully established;the implants and their superstructures were least stressed when the maxillary central incisors with partial labial and partial palatal shape were placed along the long axis of the alveolar bone in the palatal/labial position for immediate implant loading;the implants and their superstructures were least stressed when the maxillary central incisors with central shape were placed along the long axis of the tooth in the palatal position for immediate implant loading. The implant and its superstructure were subjected to the least stress when the implant was placed along the long axis of the tooth in the immediate loading position. @*Conclusion@#The bio-mechanical characteristics of the implant and its superstructure are influenced by the different socket morphology, implantation sites and axes. Therefore, in clinical practice, different implantation axes and implantation sites should be developed for different socket morphs.

15.
Acta Pharmaceutica Sinica ; (12): 1577-1585, 2023.
Article in Chinese | WPRIM | ID: wpr-978720

ABSTRACT

In 2015, the United States put forward the concept of precision medicine, which changed medical treatment from "one size fits all" to personalization, and paid more attention to personalization and drug customization. In the same year, Spritam®, the world's first 3D printed tablet, was in the market, marking the emerging pharmaceutical 3D printing technology was recognized by regulatory authorities, and it also provided a new way for drug customization. 3D printing technology has strong interdisciplinary and high flexibility, which puts forward higher requirements for pharmaceutical staffs. With the development of artificial intelligence (AI), modern society can perform various tasks, such as disease diagnosis and robotic surgery, with superhuman speed and intelligence. As a major AI technology, machine learning (ML) has been widely used in many aspects of 3D printing drug, accelerating the research and development, production, and clinical application, and promoting the new process of global personalized medicine and industry 4.0. This paper introduces the basic concepts and main classifications of 3D printing drug, non-AI drug optimization technology and ML. It focuses on the analysis of the research progress of ML in 3D printing drug, and elucidates how AI can empower the intelligent level of 3D printing drug in pre-processing, printing, and post-processing process. It provides a new idea for accelerating the development of 3D printed drug.

16.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 162-169, 2023.
Article in Chinese | WPRIM | ID: wpr-978462

ABSTRACT

ObjectiveTo observe the effects of modified Shenqiwan on renal function and fibrosis in diabetic nephropathy mice and explore the underlying mechanism based on the glycogen synthase kinase-3β (GSK-3β)/cyclic adenosine monophosphate (cAMP) response element-binding protein (CREB) signaling pathway. MethodFifty male db/db mice and 10 db/m mice were used in this study. The fifty db/db mice were randomly divided into model group, irbesartan group, and low-, medium-, and high-dose modified Shenqiwan groups. The 10 db/m mice were assigned to the normal group. The mice in the low-, medium-, and high-dose modified Shenqiwan groups were administered with modified Shenqiwan in the dosage form of suspension of Chinese medicinal granules by gavage, those in the irbesartan group were given irbesartan suspension by gavage, and those in the normal and model groups were given distilled water of equal volume by gavage. The intervention lasted for 12 weeks. The blood glucose levels, urine albumin-to-creatinine ratio (UACR), and the protein expression levels of GSK-3β, CREB, transforming growth factor-β1 (TGF-β1), E-cadherin, Vimentin, fibronectin (FN), plasminogen activator inhibitor-1 (PAI-1), and Collagen type Ⅳ (Coll Ⅳ) in the mouse kidneys were recorded before and after treatment. The extent of renal pathological damage was also observed. ResultCompared with the normal group, the model group showed significant increases in blood glucose levels, UACR levels, and the protein expression levels of GSK-3β, TGF-β1, E-cadherin, Vimentin, FN, PAI-1, and Coll Ⅳ in the kidneys (P<0.05), decreased protein expression level of CREB (P<0.05), and severe renal pathological damage. Compared with the model group, the low-, medium-, and high-dose modified Shenqiwan groups and the irbesartan group showed varying degrees of decreases in blood glucose levels, UACR levels, and the protein expression levels of GSK-3β, TGF-β1, E-cadherin, Vimentin, FN, PAI-1, and Coll Ⅳ in the kidneys (P<0.05), increased expression level of CREB protein (P<0.05), and improved renal pathological damage. ConclusionModified Shenqiwan can effectively reduce blood glucose levels, improve renal function, and alleviate fibrosis, and the mechanism of action is related to the inhibition of the GSK-3β/CREB signaling pathway.

17.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 22-30, 2023.
Article in Chinese | WPRIM | ID: wpr-976536

ABSTRACT

ObjectiveTo investigate the effect and mechanism of Shenling Baizhusan on the treatment of oligoasthenospermia with hyperuricemia (HUA). MethodThirty-two male Kunming (KM) mice were randomly divided into blank group (n=6), model group (n=6), high-dose Shenling Baizhusan group (n=7), low-dose Shenling Baizhusan group (n=7), and febuxostat group (n=6). Except for the blank group, all other groups received intraperitoneal injection of potassium oxazinate suspension (600 mg·kg-1) for 7 days. After modeling, the high-dose Shenling Baizhusan group and the low-dose Shenling Baizhusan group were orally administered with 20.14 g·kg-1 and 10.07 g·kg-1 of Shenling Baizhusan, respectively. The Febuxostat group was orally administered with 0.25 g·kg-1 of Febuxostat, while the blank group and model group were orally administered with the same volume of physiological saline. Oral administration was performed once a day for 14 consecutive days, after which samples were collected. Biochemical methods were used to measure serum uric acid (UA), superoxide dismutase (SOD) and malondialdehyde (MDA) in testicular tissue. Hematoxylin-eosin (HE) staining was used to observe the histopathological changes in testicular tissue and evaluate the spermatogenesis function. Automated sperm analyzer was used to measure sperm density and motility. Single-cell gel electrophoresis (SCGE) was used to assess sperm DNA integrity. Terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL) was used to detect testicular cell apoptosis rate. Western blot analysis was performed to measure the protein expression levels of Kelch-like ECH-associated protein 1 (Keap1), nuclear factor E2-related factor 2 (Nrf2), heme oxygenase-1 (HO-1), B-cell lymphoma-2 (Bcl-2), Bcl-2-associated X protein (Bax), and Caspase-3 in testicular tissue. Real-time polymerase chain reaction (PCR) was conducted to evaluate the mRNA expression levels of Keap1, Nrf2, and HO-1 in testicular tissue. ResultCompared with the blank group, the model group showed elevated serum UA level (P<0.01), decreased testicular spermatogenesis function, sperm density, and motility (P<0.01), and increased sperm trailing rate and testicular cell apoptosis rate (P<0.01). Compared with the model group, the high-dose Shenling Baizhusan group showed significant improvements in the above-mentioned indicators (P<0.05, P<0.01). Additionally, the expression levels of Keap1, Bax, and Caspase-3 in testicular tissue were reduced, while the expression levels of Nrf2, HO-1, and Bcl-2 increased (P<0.05, P<0.01). The mRNA level of Keap1 decreased (P<0.05, P<0.01), while the mRNA levels of Nrf2 and HO-1 increased (P<0.05, P<0.01). ConclusionShenling Baizhusan can significantly improve HUA oligoasthenospermia, and its mechanism may be related to the Nrf2/antioxidant response element (ARE) signaling pathway.

18.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 27-36, 2023.
Article in Chinese | WPRIM | ID: wpr-973742

ABSTRACT

ObjectiveTo investigate the mechanism of Buyang Huanwutang in treating diabetic peripheral neuropathy (DPN) via mitochondrial transport. MethodDiabetes in SD rats was induced by a high-carbohydrate/high-fat diet and intraperitoneal injection of streptozotocin (STZ). The 45 diabetic rats were randomly assigned into a DPN group, an alpha-lipoic acid (60 mg·kg-1·d-1) group, and a Buyang Huanwutang (15 g·kg-1·d-1) group, with 15 rats in each group. Fifteen normal SD rats were fed with the standard diet and set as the control group. The rats were administrated with corresponding drugs by gavage for 12 weeks. The paw withdraw threshold (PWT) and motor nerve conduction velocity (MNCV) were measured at the end of medication, and the sciatic nerve and the bilateral dorsal root ganglia of L4-5 were collected. The injury model of NSC34 cells was established by treating with 50 mmol·L-1 glucose and 250 μmol·L-1 sodium palmitate. The NSC34 cells were then randomly assigned into a blank (10% blank serum) group, a DPN (10% blank serum) group, an apha-lipoic acid (10% apha-lipoic acid-containing serum) group, a Buyang Huanwutang (10% Buyang Huanwutang-containing serum) group, and a Buyang Huanwutang + Compound C (CC) (10% Buyang Huanwutang-containing serum + 10 μmol·L-1 CC) group. The cell intervention lasted for 24 h. The immunofluorescence method, immunohistochemistry, and Western blot were employed to determine the expression levels of phosphorylated adenosine monophosphate-activated protein kinase (p-AMPK), phosphorylated cAMP-response element binding protein (p-CREB), kinesin family member 5A (KIF5A), and dynein cytoplasmic 1 intermediate chain 2 (DYNC1I2). ResultCompared with the control group, the DPN group of rats showed increased fasting blood glucose (P<0.01), decreased MNCV and PWT (P<0.01), down-regulated expression of KIF5A, p-AMPK/AMPK, and p-CREB/CREB (P<0.01), and up-regulated expression of DYNC1I2 (P<0.01). Compared with the DPN group, drug intervention groups showed increased MNCV and PWT (P<0.01), up-regulated expression of KIF5A, p-AMPK/AMPK, and p-CREB/CREB (P<0.05, P<0.01), and down-regulated expression of DYNC1I2 (P<0.05, P<0.01). The Buyang Huanwutang group had higher levels of MNCV and KIF5A (P<0.05) and lower level of DYNC1I2 (P<0.01) than the apha-lipoic acid group. Compared with the blank group, the DPN group of NSC34 cells showed decreased levels of KIF5A, p-AMPK/AMPK, and p-CREB/CREB (P<0.01) and increased level of DYNC1I2 (P<0.01). The apha-lipoic acid group and Buyang Huanwutang group had higher levels of KIF5A, p-AMPK/AMPK, and p-CREB/CREB (P<0.05, P<0.01) and lower level of DYNC1I2 (P<0.01) in NSC34 cells than the DPN group. Buyang Huanwutang group had higher KIF5A level (P<0.05) in NSC34 cells than the apha-lipoic acid group. Moreover, the Buyang Huanwutang + CC group had lower levels of KIF5A, DYNC1I2, p-AMPK/AMPK, and p-CREB/CREB (P<0.01) in NSC34 cells than the Buyang Huanwutang group. ConclusionBuyang Huanwutang may regulate mitochondrial anterograde transport via the AMPK/CREB pathway to prevent and treat DPN.

19.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 352-358, 2023.
Article in Chinese | WPRIM | ID: wpr-961354

ABSTRACT

Objective @#To investigate the biomechanical effects of upper lip pressure on the maxilla in patients with a unilateral alveolar cleft and provide evidence for clinical diagnosis and treatment. @*Methods @#A 3D finite element maxillary model was generated based on cone beam CT (CBCT) data from an 11-year-old female patient with a unilateral alveolar cleft. Two different kinds of upper lip pressure, postsurgery pressure and normal pressure, were applied to the model. The displacement and stress of each reference node were compared and analyzed. @*Results @# By loading upper lip pressure, the maxillary alveolar crest rotated toward the defect and was displaced downward and backward. The displacement of the noncleft side was greater than that of the cleft side and it decreased gradually from the anterior to the posterior. The stress was concentrated on the anterior portion of the alveolar crest. The stress on the noncleft side was greater than that on the cleft side and it decreased gradually from the anterior to the posterior. The maximum stress was concentrated on the palate around the defect. The displacement and stress in the postsurgery group were greater than those of the normal group (P<0.05). @*Conclusion @#By loading upper lip pressure, the maxilla demonstrated asymmetry three-dimensionally. The adverse effects on the maxilla could be mitigated by reducing the upper lip pressure.

20.
Journal of Medical Biomechanics ; (6): E465-E471, 2023.
Article in Chinese | WPRIM | ID: wpr-987972

ABSTRACT

Objective To study the process of single stent and double-stent thrombectomy at the Y-shaped bifurcation of the ideal internal carotid artery by finite element simulation, analyze the stent-thrombus-vessel interaction during the thrombectomy process based on the simulation results, and provide guidance for improving the effect of stent thrombectomy at the bifurcation. Methods The CAD software was used to build the model and the finite element analysis software was used to simulate the process of single stent and double-stent thrombectomy. Results Thrombectomy was unsuccessful in single stent model and successful in double-stent model, and the maximum stress of thrombus during embolus retrieval was twice that of single stent, the maximum strain was 1.12 times that of single stent, and the maximum contact pressure on the surface of vessel was approximately twice that of single stent. Conclusions Double Solitaire stents can effectively prevent thrombus displacement at the bifurcation and successfully retrieve the thrombus, but there is a risk of fracture due to the high stress level in the middle section of the thrombus. The contact pressure of the vessel on the anterior artery side is higher during thrombectomy, and the risk of vessel damage is greater. Therefore, it is necessary to optimize the design of the stent-retriever to improve its flexibility.